Campbell Time Series

The Campbell data logger controls MOBYs functional timing. It turns on the Falcon controller computer which will do a task depending upon the time it is powered up. The Campbell is also programed to power down the buoy at programmable times to make sure the system is shutdown at least once per day to return the system to a known state. The Falcon always boots from a cold state at power up. The Campbell operates based on a proprietary CRBasic programing language. Campbell analog Inputs measure Battery voltage, Campbell unit panel temperature, Case Air Temperature, Case Humidity, state of the Falcon Main Power Relay and state of the Charge Relay. Campbell has override control of the Main Power Relay and the Charge Relay. Campbell modem power is also controlled by the Campbell. The Campbell data table contains a record of the above parameters as well as important program flow flags. The voltage monitored by the Campbell is actually the voltage of the Campbell backup battery which is diode isolated from the Campbell and the Upper Battery. Due to the isolated battery supplies, this voltage is not much use in quantitatively monitoring the health of the Upper Battery. The Campbell backup battery only powers the Campbell when the Upper Battery falls below about 11.5 volts. The Campbell will operate down to a voltage of 10.5 volts at which point it will only try to switch the Charge Really to the Upper Battery to try and gain power for the controller rather than any lower batteries.

MainRlyState, 0=False=Off -1=True=On
ChargeRlyState, 0=False=Down -1=True=Up
MainRlyState is the feedback from the power relay controlling the Falcon
ChargeRlyState is the feedback from the charge relay that switches the PV power to the Upper or Lower batteries
kohms is a flooding sensor, it will go below 10K if the housing contains free water
Campbell battery = BattV
Solar panel (PhotoVoltaic cell) voltage = PVVolts


Reading for the last day of the file: 01-Jun-2022 23:59:00 to 31-May-2022 23:59:00 (1 day)
Measurment Mean Min Max %std
CamBattV (Volts 13.0957 12.82 13.61 0.63
PTemp_C (Deg C) 26.3656 24.38 30.66 7.00
AirTC (Deg C) 25.8004 23.6 30.92 8.14
RH (%) 26.2574 25.6 27.56 2.10
Measurment Minutes Down Minutes Up
ChargeRlyState 22.6833 1.3333
Measurment Minutes Off Minutes On
MainRlyState 19.6167 4.4

Means for the last 10 days for each day in the file (times and days from GMT time)
Day BattV PTemp_C AirTC RH kohms
29-May-2022 13.0675 28.4857 28.2816 25.9346
30-May-2022 13.0854 26.2573 26.068 25.3322
31-May-2022 13.0844 26.5102 26.0677 25.9876
01-Jun-2022 13.0957 26.3632 25.7979 26.2568

Campbell Start and Stop Times for turning on (last 20 cycles) - MainRlyState = -1
On/Off Start Time Stop Time Delta Time (hours)
Off 31-May-2022 17:18:00 31-May-2022 17:59:00 0.68
On 31-May-2022 18:00:00 31-May-2022 18:15:00 0.25
Off 31-May-2022 18:16:00 31-May-2022 20:35:00 2.32
On 31-May-2022 20:36:00 31-May-2022 21:45:00 1.15
Off 31-May-2022 21:46:00 31-May-2022 22:07:00 0.35
On 31-May-2022 22:08:00 31-May-2022 23:11:00 1.05
Off 31-May-2022 23:12:00 31-May-2022 23:44:00 0.53
On 31-May-2022 23:45:00 01-Jun-2022 00:49:00 1.07
Off 01-Jun-2022 00:50:00 01-Jun-2022 02:59:00 2.15
On 01-Jun-2022 03:00:00 01-Jun-2022 03:15:00 0.25
Off 01-Jun-2022 03:16:00 01-Jun-2022 03:59:00 0.72
On 01-Jun-2022 04:00:00 01-Jun-2022 04:17:00 0.28
Off 01-Jun-2022 04:18:00 01-Jun-2022 16:59:00 12.68
On 01-Jun-2022 17:00:00 01-Jun-2022 17:15:00 0.25
Off 01-Jun-2022 17:16:00 01-Jun-2022 17:59:00 0.72
On 01-Jun-2022 18:00:00 01-Jun-2022 18:15:00 0.25
Off 01-Jun-2022 18:16:00 01-Jun-2022 20:35:00 2.32
On 01-Jun-2022 20:36:00 01-Jun-2022 21:43:00 1.12
Off 01-Jun-2022 21:44:00 01-Jun-2022 22:07:00 0.38
On 01-Jun-2022 22:08:00 01-Jun-2022 23:11:00 1.05
Off 01-Jun-2022 23:12:00 01-Jun-2022 23:44:00 0.53

Start and Stop Times for when Falcon switches the Charge Relay (last 20 cycles) - ChargeRlyState = -1
Up/Down Start Time Stop Time Delta Time (hours)
Down 01-Jun-2022 03:14:00 01-Jun-2022 04:01:00 0.78
Up 01-Jun-2022 04:02:00 01-Jun-2022 04:15:00 0.22
Down 01-Jun-2022 04:16:00 01-Jun-2022 17:01:00 12.75
Up 01-Jun-2022 17:02:00 01-Jun-2022 17:07:00 0.08
Down 01-Jun-2022 17:08:00 01-Jun-2022 17:08:00 0.00
Up 01-Jun-2022 17:09:00 01-Jun-2022 17:09:00 0.00
Down 01-Jun-2022 17:10:00 01-Jun-2022 18:01:00 0.85
Up 01-Jun-2022 18:02:00 01-Jun-2022 18:10:00 0.13
Down 01-Jun-2022 18:11:00 01-Jun-2022 18:11:00 0.00
Up 01-Jun-2022 18:12:00 01-Jun-2022 18:13:00 0.02
Down 01-Jun-2022 18:14:00 01-Jun-2022 20:37:00 2.38
Up 01-Jun-2022 20:38:00 01-Jun-2022 20:42:00 0.07
Down 01-Jun-2022 20:43:00 01-Jun-2022 21:34:00 0.85
Up 01-Jun-2022 21:35:00 01-Jun-2022 21:41:00 0.10
Down 01-Jun-2022 21:42:00 01-Jun-2022 22:09:00 0.45
Up 01-Jun-2022 22:10:00 01-Jun-2022 22:14:00 0.07
Down 01-Jun-2022 22:15:00 01-Jun-2022 23:01:00 0.77
Up 01-Jun-2022 23:02:00 01-Jun-2022 23:08:00 0.10
Down 01-Jun-2022 23:09:00 01-Jun-2022 23:46:00 0.62
Up 01-Jun-2022 23:47:00 01-Jun-2022 23:51:00 0.07
Down 01-Jun-2022 23:52:00 01-Jun-2022 23:59:00 0.12


Stephanie Flora - Moss Landing Marine Laboratories

13-Jan-2023 10:29:03