Two classes of data are reported. Vertical CTD profiles of water column properties and water analyses for particulate materials. In addition to making
particulate analyses from CTD rosette bottles, we also report those data from samples taken from the ships sea chest during long-track horizontal profiles and while
on station. First the CTD downcast profile data is described, then the CTD upcast bottle data and lastly
the TSM/POC/PON data taken from the ships seachest while on station.
CTD Downcast Data
Symbol
|
units
|
Description
|
Salin
|
PSU
|
Seawater salinity in Practical Salinity Units,PSU (numerically equivalent to g/kg)
|
Temp
|
°C
|
In situ seawater temperature in Celsius
|
Pres
|
dbar
|
Pressure in decibars (numerically equivalent to depth in m)
|
Oxy
|
ml/l
|
Dissolved oxygen in ml/l determined by oxygen electrode
|
Fl680
|
rfu
|
In situ chlorophyll fluorescence at 680 nm in relative fluorescence units (rfu), MLML Fluorometer
|
Fl670
|
rfu
|
In situ chlorophyll fluorescence at 670 nm in relative fluorescence units (rfu), Chelsea Fluoromter
|
JulDay
|
|
Julian Day of the Year
|
GMT
|
Hours
|
Greenwich Mean Time in decimal dours
|
Sigma
|
g/l
|
Potential seawater density anomaly based on potential temperature in grams per liter
|
GeoPot
|
dynamic meters
|
Geopotential anomaly (dynamic meters)
|
Theta
|
°C
|
Potential temperature, ITS-90 (°C)
|
% OxySat
|
%
|
Oxygen saturation percentage is 100 x the ratio of observed oxygen concentration to the oxygen solubility
|
c660
|
1/m
|
The total attenuation coefficient in m-1 measured by a C-Star 25-cm transmissometer at 660 nm
|
CTD Upcast Bottle Data
Symbol
|
units
|
Description
|
Btl#
|
#
|
Bottle number from which sample was drawn
|
Btime
|
Hours
|
GMT time the bottle was tripped
|
CTD_S
|
PSU
|
Seawater salinity in Practical Salinity Units (numerically equivalent to g/kg).
|
CTD_T
|
°C
|
Bottle in situ seawater temperature in Celsius
|
CTD_P
|
dbars
|
Bottle pressure in decibars (numerically equivalent to depth in m)
|
CTD_O
|
ml/l
|
Bottle dissolved oxygen in ml/l determined by oxygen electrode
|
CTD_F680
|
rfu
|
Bottle chlorophyll fluorescence at 680 nm in relative fluorescence units (rfu), MLML Fluorometer
|
CTD_F670
|
rfu
|
Bottle chlorophyll fluorescence at 680 nm in relative fluorescence units (rfu), MLML Fluorometer
|
CTDC660
|
1/m
|
Bottle total attenuation coefficient at 660 nm in 1/m
|
CTDwoxy
|
ml/l
|
Bottle oxygen in ml/l determined by Winkler titration
|
CTDTSM
|
mg/l
|
Total suspended material in milligrams per liter
|
CTDTSMV
|
l
|
Volume filtered in liters for the determination of TSM
|
CTDPOC
|
µg/l
|
Particulate Organic Carbon in micrograms per liter
|
CTDPON
|
µg/l
|
Particulate Organic Nitrogen in micrograms per liter
|
CTDPOCV
|
l
|
Volume filtered in liters for the determination of POC and PON
|
CTD_C/N
|
|
Molar Carbon to Nitrogen Ratio
|
CTD_OM
|
µg/l
|
Organic Matter
|
CTD_%OM
|
%
|
Percent Organic Matter
|
Total Suspended Material and Particulate Organic
Carbon and Nitrogen samples taken from the ship's sea chest
Symbol
|
units
|
Description
|
Date
|
YYMMDD
|
The GMT date the sample was collected in the format YYMMDD, where YY is the 2 digit year, MM is the month and DD is the day.
|
Time
|
Hours and Minutes
|
GMT time sample was collected in the format HH.MM, where HH is the hour and MM is the minutes.
|
Latitude
|
DD.MMm
|
Latitude in DD.MMm were DD is degrees and MMm is decimal minutes. North is positive and South is negative.
|
Longitude
|
DD.MMmm
|
Longitude in DD.MMm were DD is degrees and MMm is decimal minutes. East is positive and West is negative
|
Depth
|
m
|
Depth of sample collected, ship sea chest is 5 meter, bucket samples are 0 meters
|
TSM
|
mg/l
|
Total Suspended Material
|
Vol
|
l
|
Water filtered for Total Suspended Material
|
POC
|
µg/l
|
Particulate Organic Carbon
|
PON
|
µg/l
|
Particulate Organic Nitrogen
|
Vol
|
l
|
Water filtered (l) for POC and PON
|
OM
|
µg/l
|
Organic Matter
|
%OM
|
%
|
Percent by weight of organic matter in TSM
|
C/N ratio
|
|
Molar Carbon to Nitrogen Ratio
|