MOBYrefresh - BS01 Configurations


MOBY-Refresh will have 4 each blue and red specs - BS01, BS02, BS03, BS04 and RS01, RS02, RS03, RS04
Exp
Exp#
Config link Description

Date Added

timeline 1.01 BS1 timeline PDF MOBYrefresh BS01 information document 4/27/2015
Intial Resonon 1.02 002 sphere May 2015 email: sphere file - email from Mike with first test images (all tracks illuminated) 12/3/2015
Intial Resonon 1.03 002 channel 7 May 2015 email: Channel 7 file - email from Mike with first test images (Only track 7 illuminated) 12/7/2015
Intial Resonon 1.04 002 helium_blue May 2015 email: helium blue file - blue line unsat (all tracks illuminated) 12/7/2015
Intial Resonon 1.05 002 helium_red May 2015 email: helium red file - red line unsat, blue line low but usable (all tracks illuminated) 12/7/2015
Intial Resonon 1.07 002 PDF June 16 2016 email: Resonon reports on BS1 and BS2 6/16/2016
Arrived in Hawaii on 14 March 2016
Hawaii-2015-01 2.01 001 webpage Hawaii-2015-01 - wavecal, laser, saturation, Gain, cross track, infrared artifact 5/6/2016
Back from Resonon with better track focus
Hawaii-2015-03 3.01 002 webpage Hawaii-2015-03 - wavecal, laser, FO splitter, polarizer, solar, Readout rates and shift speeds 5/6/2016
Back from Resonon - added 350-700 nm filter
Hawaii-2016-02 4.01 003 webpage Hawaii-2016-02 - reshipment testing, laser, Oriel, repeatability, Pen lamp wavecal, polarizer, solar 5/6/2016
Arrived in Miami with loose resonon tube shipping, Ken decided there was no damage, loose tube is attributed to short screws
Miami-2016-01 5.01 004 webpage Miami-2016-01 - Hg(A) lamp and solar data (wave and track movement) 5/6/2016
Sent from Miami Back to Resonon. Resonon replaced the the Schrader valve on BS01, and realigned the unit. Mike replaced the screws that hold the camera mount in place with slightly longer ones, and when I was tightening them as one of them felt a bit 'mushy'. No data where collected at Resonon. Then shipped to Mike in Hawaii. 14-Sep-2016 Arrived in Hawaii: Mike says "The condition of the packing job was not optimal."
Hawaii-2016-09 6.01 005 webpage Hawaii-2016-09 - Intial testing after return from Resonon and preM261 testing  
Hawaii-2017-01 7.01 006 & 007 webpage Hawaii-2017-01 - Characterizations and testing in preparation for deployment on MOBY262  
MOBY262 8.01 007 webpage In MOBY262 during deployment. No clocks installed in BS01  
MOBY-L264 9.01 007 webpage MOBY262 postcal data sets ( wacecal, int time, rsp)  
MOBY-L267 10.01 008 webpage MOBY-L267 check for UV ghosting and fiber mode (vert/horiz)  
BS01 sent back to Andor have wedged window installed then to Resonon for re-alignment
Exp
Exp#
Config link Description

Date Added

2nd Resonon 11.02 100 sphere Sep 2019 email: sphere file - email from Mike with first test images (all tracks illuminated) 09/19/2019
2nd Resonon 11.03 100 channel 7 Sep 2019 email: Channel 7 file - email from Mike with first test images (Only track 7 illuminated) 09/19/2019
2nd Resonon 11.04 100 helium_blue Sep 2019 email: helium blue file - blue line unsat (all tracks illuminated) 09/19/2019
2nd Resonon 11.05 100 shake test Sep 2019 email: Looking at the wavelength and spactial shake test 09/19/2019
2nd Resonon 11.07 100 PDF Sep 2019 email: Resonon reports on BS01 after repair 09/19/2019
There was a lot of track movement on the first shake test. So they torqued the screws that hold the camera to their maximum and re-shook BS01.
Exp
Exp#
Config link Description - Oct 2019 email: sphere file 2nd shake

Date Added

2nd Resonon 11.02 101 sphere All tracks sphere illuminated test 10/17/2019
2nd Resonon 11.03 101 channel 7 Channel 7 file - email from Mike with first test images (Only track 7 illuminated) 10/17/2019
2nd Resonon 11.04 101 helium_blue helium blue file - blue line unsat (all tracks illuminated) 10/17/2019
2nd Resonon 11.05 101 shake test 2 Comparing pre-shake 2 to all the post-shake 3 10/17/2019
2nd Resonon 11.06 101 shake test 1,2,3 Comparing pre-shake 1 to all the post-shakes (1,2,3) - may not be representative 10/17/2019
2nd Resonon 11.07 101 PDF Resonon reports on BS01 after repair and torqued screws 10/17/2019
BS01 arrived in Hawaii on 15 Oct 2019 - visually in good condition

 

System configuration documents etc
Link Description Date
Performance doc for the Andor camera Andor Camera performance doc - DU934P-BR-DD (SN: CCD-17878) - BS01cfg002,3 and 4 13 Apr 2016
Performance doc for the Andor camera Andor Camera performance doc - DU934P-BR-DD (SN: CCD-16346) - BS01cfg001 6 May 2016
Photos of BS01 second arrival in Hawaii Mikes photos of the BS04cfg005 system upon arrival in Hawaii, after a trip to Miami and then Resonon. Mike says "The condition of the packing job was not optimal." 14 Sep 2016
     

Notes, documents and emails:

Filter installed on the rear tilted substrate of all of the BS systems. It made the filter on the front face of Prism 1 redundant and hence no such filter is reported for BS6. (BS5 and BS6 used prisms from a different batch.). Some of the early systems were brought back into our lab to have this rear filter installed.  

BS01 --> UV ghosting from mirrored tracks - Hawaii-2017-01 - Page number 5.06